Konica Minolta Cl 200a User Manual

2021. 6. 2. 10:44카테고리 없음

  1. Konica Minolta Cl-200a Manual
  2. Konica Minolta Cl-200 Manual
  3. Konica Minolta Cl 500a
  4. Konica Minolta Manual Pdf
  5. Konica Minolta Cl 200a

CL-S10w (Standard accessory) Use the CL-500A for CRI (color rendering index) evaluation! Comprehensive software included Illuminance Spectrophotometer CL-500A Measures color-rendering properties Chroma Meter CL-200A Measures color temperature Illuminance Meter T-10A Konica Minolta's Illuminance Measurement Trio. This website uses cookies to enhance your visiting experience on our site. For more details, or to find out how to disable cookies please follow this link. Please note that by deleting our cookies or disabling future cookies you may not be able to access certain areas or features of our site. Chroma Meter CL-200A. The CL-200A Chroma Meter, the next generation to the CL-200, measures the chromaticity of light sources such as LED, Organic LED (OLED), and other forms of Organic Electroluminescence (EL) as well as color temperature and illuminance.

Konica Minolta Cl-200a Manual

Advertising

Compact and easy to carry

The CL:200A's compact
body fits in your palm.
Battery-powered so it can
be taken along and used
anywhere.

Konica Minolta Cl-200 Manual

Detachable receptor head

The receptor head can be detached and then
connected to the main body using a normal LAN
cable*, making it easy to install the sensor in an
inspection system.

* Optional Adapter Units required for receptor head and

main body

Data transfer using main

body buttons

When using the CL-200A with Data Management
Software CL-S10w (included), measurements can be
taken and data transferred to Excel

®

using the main

body buttons as well as computer keys.

Easy, convenient Excel

®

add-in

Measurement data from the CL-200A can be transferred directly
into Excel

®

. The transferred data can then be managed freely

within Excel

®

.

Includes LED ranking function

Color variations, the top topic in the LED industry, can be quantified
and a ranking function is also provided.

JIS correlated color temperature

Correlated color temperature is determined using the equations
defined by JIS (Japanese Industrial Standards).

Multi-point measurement and

user calibration also possible

Multi-point measurement management using up to 30 receptor
heads is possible.
User calibration function enables compensation of measurement
values to match a desired standard. Calibration can be performed
by two methods: Single-point calibration or RGB calibration.

Excel

®

add-in software included

PASS

FAIL

PASS

FAIL

OK!

Data Management Software

CL-S10w

(Standard accessory)

Konica Minolta Cl 500a

De facto industry standard for measuring

Konica Minolta Cl 200a User Manual

color temperature!

Advertising
Konica Minolta Cl 200a User Manual
Popular Brands
Popular manuals
Konica Minolta Updated: 2008-12-24 RSS

Handheld and lightweight instrument for color, illuminance and color temperature measurements.

The portable Konica Minolta color meters are in their element when not only the brightness but also the color of light is to be measured. The wide selection offers the appropriate instrument for every application, from the simple tristimulus unit up to a spectroradiometer with spectral lenses.

Areas of application
Practically anything that illuminates can be measured with Konica Minolta's incident color meters. The possible uses range from research and development to production.
The CL-200 is a lux meter with a color function for workplace and street illumination, the production of lamps, or the measurement of very large surfaces and projectors (ANSI lumens) by taking advantage of the serial connection of several receptor heads.

Handheld and lightweight instrument for color, illuminance and color temperature measurements
The CL-200 is a Incident Color Meter designed to measure and display the tristimulus values, chromaticity, color difference, correlated color temperature and illuminance of light sources. Applications include research and development and color inspection of light sources whether for manufacture or end use, setting up and adjustment of projectors and other display devices and environmental and psychological experimentation and testing.

The CL-200 is a replacement for two instruments - the CL-100 and XY-1- and includes many new features. Immediate measurement is possible from turning on the unit by quick automatic zero adjustment so it is always ready to move at the speed of light. Sometimes it is necessary to measure remotely for matters of safety or convenience so the CL-200 receptor can be separated and connected up to 100m away from the measuring body by LAN cable. An RS-232 interface is built in to allow connection to PC and connection to thermal printer is also optional should a printout of measured data be required for validation.

Minolta mn12z manual

Konica Minolta Manual Pdf

Like the T-10 range of Konica Minolta illuminance meters, the CL-200 allows multi-point measurement - from 2 to 30 additional receptors connected to one main body. This is particularly useful should the operator wish to measure light across a large area, like the whole of a projector screen, for example or light falling across a room or open field.

The Incident Color Meter CL-200 supports measurement of the tristimulus values, chromaticity, color difference, correlated color temperature, and illuminance of light sources.

Principal Applications

* R&D for projector light sources.
* Control of color quality for CRTs and color LCDs
* Examination of light boxes for color change over time
* R&D and quality control for fluorescent lights
* Control of light boxes for color evaluation purposes
* R&D for building and interior lighting products
* Evaluation of experimental psychological environments

Main Features

Konica Minolta Cl 200a

* Four calibration functions for correction of measurement values.
Normal calibration: Measurement values are corrected using a standard A-source as the calibration light source
Normal user calibration: Measurement values are corrected by input of calibration light-source values
Multi calibration: Measurement values are corrected using R, G, B, and W values from an ultra-high-pressure mercury lamp.
Multi user calibration: Measurement values are corrected using R, G, B, and W values from a calibration light source.
* Data Management Software CL-S1w (sold separately) is required in order to input correction values for multi user calibration.
* Automatic zero-adjustment without a receptor cap
As soon as the power is turned on, the CL-200 automatically carries out zero adjustment and calibration, even when a cap has not been attached to the receiver, thus allowing measurement operations to be started almost immediately.
* Main unit and receiver can be separated and connected using a commercially-available LAN cable.
The receiver can be positioned away from the main unit in order to carry out remote measurement (100 m maximum).
*: An Adapter Unit for Main Body T-A20 and Adapter Unit for Receptor Head T-A21 (sold separately) will be required.
* * Two-way RS-232C communication
Featuring an RS-232C interface as standard, the CL-200 can be connected to a PC in order to carry out data processing. Even in situations where multi-point measurement is carried out, batch processing can be carried out on measurement data from a number of different receivers.
*: A Connecting Cable T-A11 (sold separately) will be required in order to carry out RS-232c communication.
* Printed output
Hard copies of measurement data can be obtained by simply connecting your CL-200 to a commercially-available printer (fitted with an RS-232c terminal).
*: A Printer Cable T-A12 (sold separately) will be required in order to perform printer output.
* Key cover for worry-free operation
A sliding key cover can be used to hide the CL-200's multi-function keys when not in use, thus preventing them from being accidentally pressed.
* LCD backlight is automatically controlled for low illuminance and hold.
* Power is supplied either using AA batteries or an AC adapter (sold separately).
* Simple, low-cost, and capable of multi-point measurements.
A single unit used for data display and key operations can be connected to as many as 30 receivers.
* An Adapter Unit for Main Body T-A20 and Adapter Unit for Receptor Head T-A21 for each receptor head (sold separately) will be required for multi-point measurements.
* Dedicated PC software for a complete system
The Data Management Software CL-S1w (sold separately) can be used to display measurement values in real time; to control up to 30 multi-point measurements; to perform ANSI measurement; to set measurement intervals; and to specify standard, upper limit, and lower limit values.

Download Now
User Manual
CL-200 Chroma Meter
Related Manuals
Konica Minolta LS-100/LS-110 Luminance Meters
Konica Minolta UM-10 UV Radiometer
Konica Minolta CA-210 Display Color Analyzer
Konica Minolta CA-100Plus CRT Color Analyzer
Konica Minolta CA-2000 2D Color Analyzer
Konica Minolta CS-2000 Spectroradiometer
Konica Minolta CS-2000A Spectroradiometer
Konica Minolta CS-200 Luminance Color Meters
Konica Minolta CS-100A Luminance Color Meter
Konica Minolta RANGE7 Non-contact 3D Digitizer
Konica Minolta VIVID 9i Non-contact 3D Digitizer
Konica Minolta VIVID 910 Non-contact 3D Digitizer